Products

Series DM2ŽE, Size 2 Control Reliable



Double Valves With Dynamic Monitoring & Memory





Features

  • Dynamic Monitoring With Memory: Memory, monitoring and air flow control functions are integrated into two identical valve elements. Valves lockout if asynchronous movement of valve elements occurs during actuation or de-actuation, resulting in a residual outlet pressure of less than 1% of supply.
  • An Action Is Required For Reset: Cannot be reset by removing and re-applying supply pressure or electrical power. Reset can only be accomplished by the integrated electrical (Solenoid) reset.
  • Basic 3/2 Normally Closed Valve Function: Dirt tolerant, wear compensating poppet design for quick response and high flow capacity. TeflonŽ back-up rings on pistons to enhance valve endurance - operates with or without inline lubrication.
  • Status Indicator (Optional): Includes a pressure switch with both N.O. & N.C. contracts to provide status feedback to the press control system indicating whether the valve is in the lockout or ready-to-run condition. The status indicator can be ordered installed or purchased separately.
  • Silencers: All models include high flow, clog resistant silencers.
  • Mounting: Inline mounted - with BSPP or NPT pipe threads. Inlet and outlet ports on both sides provide for flexible piping (plugs for unused ports included).




    Standard Specifications

  • Temperature Range- Ambient: 15 to 122°F (4 to 50°C) Media: 40 to 175°F (4 to 80°C)
  • Flow Media - Filtered (5 micron recommended), lubricated or un-lubricated air (mineral oils according to DIN 51519, viscosity classes 32-46)
  • Pressure Switch (Status Indicator) Rating: Contacts - 5 amps at 250 volts AC,
    or 5 amps at 30 volts DC
  • Standard Voltages - 110 VAC, 50/60 Hz; 20 VDC
  • Solenoids: According to VDE 0580. Enclosure rating according to DIN 400 50 IP65. Connector socket according to DIN 43650 Form A. Three solenoids, rated for continuous duty.
  • Pilot Solenoid Power Consumption (each solenoid): 60W on DC; 13.6 VA inrush
    and 8.5 VA holding on AC.
  • Reset Solenoid Power Consumption: 60W on DC; 14.6 VA inrush and 8.5 VA holding on AC.

    < previous  |  next >